The order for getting fibre channel based hypervolume extentions (HVEs) viewable on systems, particularly SUN systems, is as follows:
Front Director Paths (4):
{
----------------------------------------------------------------------
POWERPATH DIRECTOR PORT
--------- ---------- -------- ------------
PdevName Type Num Type Num Sts VBUS TID LUN
----------------------------------------------------------------------
Not Visible N/A 03A FA 0 RW 000 00 70
Not Visible N/A 14A FA 0 NR 000 00 70
Not Visible N/A 03B FA 0 NR 000 00 70
Not Visible N/A 14B FA 0 NR 000 00 70
}
The number you're looking for is under the column LUN. Remember, it's HEX, so the lun that'll show up on the ctd is (0x70=112) c#t#d112You can specify multiple EMC device ranges; just separate them by spaces, not commas